Electric Wiring Test 
Grade for wiring two 3-way switches and a 4-way switch to control a light. Also, a receptacle is to be protected by a GFCI receptacle. All devices are on one 15 amp circuit.
Rubric Code: KXC2958
Ready to use
Public Rubric
Subject: Vocational  
Type: Project  
Grade Levels: 9-12

Powered by iRubric Box / Outlet / Device Wiring
Wiring diagram complete, boxes at proper heights, wire properly run, spliced, and terminated.
  Unsatisfactory

1 pts

Substandard

2 pts

Average

3.5 pts

Above Average

4 pts

Excellent

5 pts

Wire sheathed at proper length

Sheathed at minimum of 6" and maximum of 8".

Unsatisfactory

Less than 3 inches or less
or greater than 10". Cable jacket more than 3".
Substandard

Length is 3-5 inches. Cable jacket more than 2".
Average

Length is 5-5.5 inches or 8 to 10 inches. Cable jacket more than 1".
Above Average

Length is 6-8 inches. Cable jacket more than 1/4".
Excellent

All wire to 6-8" and only 1/4" of jacket in box.
Wire on devices

To much insulation stripped which exposes wire after connection.

Unsatisfactory

More than three conductors.
Substandard

3 conductors.
Average

2 conductors.
Above Average

1 conductor.
Excellent

No conductors.
GFCI wiring

Line / Load wiring for protection

Unsatisfactory

Ground not connected.
Substandard

Any of the wires hooked to the wrong terminal.
Average

All wires hooked to correct terminals with little guidance needed.
Above Average

All wires hooked to the correct terminals.
Excellent

All wires hooked to correct terminals and insulation stripped to minimum.
3-way Switch wiring

If not wired properly it won't work.

Unsatisfactory

Could not get switch to work.
Substandard

Tried three times after check to get switches to work.
Average

Tried twice after check to get switches to work.
Above Average

Tried once after check to get switches to work.
Excellent

3-way switches and light worked correctly first time.
Outlet/switch wire connection

Wires were curved and put on the terminals with curve going with tightening direction

Unsatisfactory

More than 4 connections going the wrong way on screw.
Substandard

3-4 connections going the wrong way on screw.
Average

1-2 connections going wrong way on screw.
Above Average

All connections correct.
Excellent

All connections correct and tight.
Wire Nut connection

Both wires are tight in the nut, no loose wire.<BR>
No bare wire showing.

Unsatisfactory

More than two loose and/or bare wires.
Substandard

2 loose and/or bare wires.
Average

1 loose and/or bare wire.<BR>
Connections tight but two bare wires
Above Average

No loose or bare wires.
Excellent

No loose or bare wires and splices stuffed neatly into box.
Boxes

Switch and outlet boxes mounted at correct height and correct depth.

Unsatisfactory

None were at correct height or the correct depth.
Substandard

1 was at correct height or correct depth.
Average

2 were at correct height or the correct depth.
Above Average

3 were at correct height or the correct depth.
Excellent

All were at correct height and the correct depth.
Running wire properly

NM cable was run properly and supported per NEC.

Unsatisfactory

Needed too much help to do it correctly.
Substandard

Needed help to do it correctly.
Average

Needed two adjustments.
Above Average

Needed one minor adjustment.
Excellent

Done right the first attempt. Wiring was done as per instructions.
Wiring Diagram

The wiring diagram was complete and neat. Incomplete or no wiring diagram = no shop.

Unsatisfactory

No wiring diagram.
Substandard

Wiring diagram had too many errors.
Average

Wiring diagram was done but needed a few adjustments or wiring not correct.
Above Average

Wiring diagram was complete and all wires were properly run.
Excellent

Wiring diagram complete, neat, and wires were accurately labeled.
Enter Title

NM cable securing.

Unsatisfactory

4 or more staples does not meet the NEC requirements.
Substandard

3- staples does not meet the NEC requirements.
Average

2- staples does not meet the NEC requirements.
Above Average

1- staple does not meet the NEC requirements.
Excellent

All cables are secured in a workman like manner.




Subjects:

Types:





Do more with this rubric:

Preview

Preview this rubric.

Edit

Modify this rubric.

Copy

Make a copy of this rubric and begin editing the copy.


Print

Show a printable version of this rubric.

Categorize

Add this rubric to multiple categories.

Bookmark

Bookmark this rubric for future reference.
Assess

Test run

Test this rubric or perform an ad-hoc assessment.

Grade

Build a gradebook to assess students.

Collaborate

Apply this rubric to any object and invite others to assess.
Share

Publish

Link, embed, and showcase your rubrics on your website.

Email

Email this rubric to a friend.

Discuss

Discuss this rubric with other members.
 

Do more with rubrics than ever imagined possible.

Only with iRubrictm.

n243