One Switch, Two Lights 
Students wire a single-pole switch that controls two lights.
Rubric Code: N24AW3B
Ready to use
Public Rubric
Subject: Vocational  
Type: Assessment  
Grade Levels: 9-12

Powered by iRubric One Switch, Two Lights
  Poor

1 pts

Fair

2 pts

Good

3 pts

Excellent

4 pts

Boxes

Box height and installation

Poor

Boxes are mounted at the wrong height. At least one notch is behind the front of the 2x4 and crooked.
Fair

Box heights are within an inch. Notches are in front of the 2x4, but are either too far out or crooked.
Good

Box heights are within a half-inch. Notches are aligned with the front of the 2x4, but are crooked.
Excellent

Box heights are accurate. Notches are aligned with the front of the 2x4 and are straight.
Cable

Cable selection, cable length, cable support

Poor

The wrong cable was installed. Not enough cable is installed in any boxes. The cable is not supported within 12" of each box.
Fair

The correct cable is installed in at least 1 box. Enough cable is installed in at least 1 box. The cable is supported within 12" of at least 1 box.
Good

The correct cable is installed in at least 2 boxes. At least 2 boxes have enough cable installed. At least 2 boxes have their installed cable supported within 12".
Excellent

The correct cable is installed. All boxes have at 8-10 inches of cable installed. The cable is supported within 12" of each box.
Wire

Wire stripping, hooks, jacket length

Poor

Too much insulation is stripped in each box. The hooks are improperly formed in each box. The jacket length is too long / short in each box.
Fair

The proper amount of insulation is stripped in at least one box. The hooks are all properly formed in at least one box. The jacket length is correct in at least one box.
Good

The proper amount of insulation is stripped in at least two boxes. The hooks are all properly formed in at least two boxes. The jacket length is correct in at least two boxes.
Excellent

The proper amount of insulation is stripped in all boxes. The hooks are all properly formed in all boxes. The jacket length is correct in all boxes.
Device Connection

Switch wiring, light wiring, proper terminations

Poor

The incorrect switch is used. The switch and lights are incorrectly wired. None of the terminations are on the correct way nor were they tight.
Fair

The correct switch is used. The switch is wired incorrectly. None of the terminations are on the correct way nor were they tight.
Good

The correct switch is used. The switch is wired correctly. None of the termination are on the correct way but are tight.
Excellent

The correct switch is used. The switch is wired correctly. The terminations are on the correct way and are tight.
Safety

Safety glasses, shoes, tool use, shop rules

Poor

No safety glasses. Any violation of any shop rule equals instant zero for this row.
Fair

Safety glasses. Wrong shoes. Incorrect tool use at any point in the project.
Good

Safety glasses. Close-toed shoes. Incorrect tool use at any point in the project.
Excellent

Safety glasses. Close-toed shoes. Correct tool use during the entire project.




Subjects:

Types:





Do more with this rubric:

Preview

Preview this rubric.

Edit

Modify this rubric.

Copy

Make a copy of this rubric and begin editing the copy.


Print

Show a printable version of this rubric.

Categorize

Add this rubric to multiple categories.

Bookmark

Bookmark this rubric for future reference.
Assess

Test run

Test this rubric or perform an ad-hoc assessment.

Grade

Build a gradebook to assess students.

Collaborate

Apply this rubric to any object and invite others to assess.
Share

Publish

Link, embed, and showcase your rubrics on your website.

Email

Email this rubric to a friend.

Discuss

Discuss this rubric with other members.
 

Do more with rubrics than ever imagined possible.

Only with iRubrictm.

n243