Skip to main content
sign in
Username
Password
forgot?
Sign up
Share
help_outline
help
Pricing
Request Info
Please enable JavaScript on your web browser
menu
iRubric: Preparing Sterile Drug Vials rubric
find rubric
Your browser does not support iframes.
edit
print
share
Copy to my rubrics
Bookmark
test run
assess...
delete
Do more...
Preparing Sterile Drug Vials
Aseptic Technique
Preparing sterile drug vials
Rubric Code:
JX679B8
By
amckissen
Ready to use
Public Rubric
Subject:
Vocational
Type:
(Other)
Grade Levels:
Undergraduate
Your browser does not support iframes.
Desktop Mode
Mobile Mode
Aseptic Technique
Not Acceptable
1 pts
Needs Improvement
3 pts
Acceptable
5 pts
Gathers Equipment
Not Acceptable
Does not gather needed equipment. Needs reminding of materials needed for skill. seems lost
Needs Improvement
Gathers most materials. Identifies items are needed or excess materials gathered.
Acceptable
Gathers all necessary equipment to correctly perform skill.
Place items in flow hood correctly
Not Acceptable
Improper placement of items in flow hood.
Asks questions regarding proper placement of items in flow hood.
Needs Improvement
Recognizes improper placement of items in flow hood. Identifies problem, corrects problem or explains proper procedure.
Acceptable
Places all items in flow hood correctly for use.
Clean entry areas
Not Acceptable
Does not clean areas for needle entry.
Cleans areas for needle entry improperly.
Needs Improvement
Identifies missed cleaning of needle entry area(s) and proper procedure and corrective action in practice.
Acceptable
Cleans all needle entry areas properly.
Prepare syringe
Not Acceptable
Does not open syringe correctly. Does not draw up diluent correctly. Ex: large bubbles, improper reading.
Needs Improvement
Opens syringe correctly. Draws up diluent with minor, but acceptable error, as described in lecture/reading.
Acceptable
Opens syringe properly. Draws up diluent accurately.
Placing Venting Needle
Not Acceptable
Does not place venting needle in proper area of stopper.
Needs Improvement
Improper placement of venting needle. Student identifies errors and correct technique is described.
Acceptable
Venting needle is properly placed off to the side of "bullseye" on rubber stopper.
Adds diluent to powdered medication
Not Acceptable
Does not add diluent in a manner that is acceptable. Seems lost/confused.
Needs Improvement
Adds diluent to acceptable degree. Medication is not prepared completely based on criteria described in lecture/ reading.
Acceptable
Prepares medication exactly as learned.Medication is ready to use.
Drawing up correct volume of med
Not Acceptable
Does not draw up medication properly. Wrong volume of medication is drawn up. Air bubbles are not removed.
Needs Improvement
Draws up medication without proper technique (crosses over, etc.) but identifies error.
Acceptable
Draws up medication with proper technique. No air bubbles.
Crossing over/general
Not Acceptable
Crosses over constantly. Constantly interupts air flow. Medication is contaminated.
Needs Improvement
Crosses over 1-2 times. Medication may be contaminated.
Student identifies errors and correct technique is described.
Acceptable
Does not cross over or interrupt air flow.
Keywords:
Aseptic Technique
Subjects:
Vocational
Types:
(Other)
Discuss this rubric
You may also be interested in:
More rubrics by this author
More Vocational rubrics
More (Other) rubrics
Do more with this rubric:
Preview
Preview this rubric.
Edit
Modify this rubric.
Copy
Make a copy of this rubric and begin editing the copy.
Print
Show a printable version of this rubric.
Categorize
Add this rubric to multiple categories.
Bookmark
Bookmark this rubric for future reference.
Assess
Test run
Test this rubric or perform an ad-hoc assessment.
Grade
Build a gradebook to assess students.
Collaborate
Apply this rubric to any object and invite others to assess.
Share
Publish
Link, embed, and showcase your rubrics on your website.
Email
Email this rubric to a friend.
Discuss
Discuss this rubric with other members.
Do more with rubrics than ever imagined possible.
Only with iRubric
tm
.
Copyright © 2024
Reazon Systems, Inc.
All rights reserved.
n16
Your browser does not support iframes.
Your browser does not support iframes.
Your browser does not support iframes.