Skip to main content
iRubric: Preparing Sterile Drug Vials rubric

iRubric: Preparing Sterile Drug Vials rubric

find rubric

edit   print   share   Copy to my rubrics   Bookmark   test run   assess...   delete   Do more...
Preparing Sterile Drug Vials 
Preparing sterile drug vials
Rubric Code: JX679B8
Ready to use
Public Rubric
Subject: Vocational  
Type: (Other)  
Grade Levels: Undergraduate

Powered by iRubric Aseptic Technique
  Not Acceptable

1 pts

Needs Improvement

3 pts

Acceptable

5 pts

Gathers Equipment

Not Acceptable

Does not gather needed equipment. Needs reminding of materials needed for skill. seems lost
Needs Improvement

Gathers most materials. Identifies items are needed or excess materials gathered.
Acceptable

Gathers all necessary equipment to correctly perform skill.
Place items in flow hood correctly

Not Acceptable

Improper placement of items in flow hood.
Asks questions regarding proper placement of items in flow hood.
Needs Improvement

Recognizes improper placement of items in flow hood. Identifies problem, corrects problem or explains proper procedure.
Acceptable

Places all items in flow hood correctly for use.
Clean entry areas

Not Acceptable

Does not clean areas for needle entry.
Cleans areas for needle entry improperly.
Needs Improvement

Identifies missed cleaning of needle entry area(s) and proper procedure and corrective action in practice.
Acceptable

Cleans all needle entry areas properly.
Prepare syringe

Not Acceptable

Does not open syringe correctly. Does not draw up diluent correctly. Ex: large bubbles, improper reading.
Needs Improvement

Opens syringe correctly. Draws up diluent with minor, but acceptable error, as described in lecture/reading.
Acceptable

Opens syringe properly. Draws up diluent accurately.
Placing Venting Needle

Not Acceptable

Does not place venting needle in proper area of stopper.
Needs Improvement

Improper placement of venting needle. Student identifies errors and correct technique is described.
Acceptable

Venting needle is properly placed off to the side of "bullseye" on rubber stopper.
Adds diluent to powdered medication

Not Acceptable

Does not add diluent in a manner that is acceptable. Seems lost/confused.
Needs Improvement

Adds diluent to acceptable degree. Medication is not prepared completely based on criteria described in lecture/ reading.
Acceptable

Prepares medication exactly as learned.Medication is ready to use.
Drawing up correct volume of med

Not Acceptable

Does not draw up medication properly. Wrong volume of medication is drawn up. Air bubbles are not removed.
Needs Improvement

Draws up medication without proper technique (crosses over, etc.) but identifies error.
Acceptable

Draws up medication with proper technique. No air bubbles.
Crossing over/general

Not Acceptable

Crosses over constantly. Constantly interupts air flow. Medication is contaminated.
Needs Improvement

Crosses over 1-2 times. Medication may be contaminated.
Student identifies errors and correct technique is described.
Acceptable

Does not cross over or interrupt air flow.



Keywords:
  • Aseptic Technique

Subjects:

Types:





Do more with this rubric:

Preview

Preview this rubric.

Edit

Modify this rubric.

Copy

Make a copy of this rubric and begin editing the copy.


Print

Show a printable version of this rubric.

Categorize

Add this rubric to multiple categories.

Bookmark

Bookmark this rubric for future reference.
Assess

Test run

Test this rubric or perform an ad-hoc assessment.

Grade

Build a gradebook to assess students.

Collaborate

Apply this rubric to any object and invite others to assess.
Share

Publish

Link, embed, and showcase your rubrics on your website.

Email

Email this rubric to a friend.

Discuss

Discuss this rubric with other members.
 

Do more with rubrics than ever imagined possible.

Only with iRubrictm.



Copyright © 2024 Reazon Systems, Inc.  All rights reserved.
n16