Skip to main content

iRubric: Anesthesia Procedures rubric

find rubric

(draft) edit   print   share   Copy to my rubrics   Bookmark   test run   assess...   delete   Do more...
Anesthesia Procedures 
Injectable and Gas Anesthetic Procedures
Rubric Code: F55X47
Draft
Public Rubric
Subject: Test Preparation  
Type: Assessment  
Grade Levels: Undergraduate

Powered by iRubric Anesthesia Procedures
  Good

3 pts

Fair

2 pts

Poor

1 pts

Records

Good

•Correct information was logged with black or blue ink
•The record was legible and able to be interpreted
•If a mistake was made, it was crossed out with a single line, and initialed.
•Drug balance was correctly calculated after each entry
Fair

Minimal mistakes were made and corrected, logging was done with black or blue ink. Drug balance was correct.
Poor

Several mistakes were made while logging. Balance was entered incorrectly.
Anesthetic Machine Prepartation

Good

•The student checked the oxygen source
•The student turned the oxygen on and verified the oxygen pressure gauge was working
•Checked the vaporizer for inhalent
•Breathing system and breathing bag were properly attached
•Scavenger was connected properly
•The student performed a low-pressure leak test
•The student opened the pop-off valve
Fair

Oxygen and gas levels were checked. Breathing tubes and bag were checked for proper attachment. Low pressure leak test was completed.
Poor

Oxygen and gas levels were checked.
Inhalent Anesthetic Preparation

Good

•Endotracheal tubes of appropriate size for the patient to be anesthetized were for leaks(For felines, lidocaine spray/gel and a stylet are ready for intibation)
•Gauze is near the endotracheal tubes for use in tying the tube.
•A syringe is near the endotracheal tubes for use in filling the cuff after intubation
•Anesthesia record was prepared and placed it at the area for induction
•Anethesia induction agent was ready to administer at time of induction
Fair

Endotracheal tube was selected. Gauze, syringe and record are present
Poor

Several items were missing for proper induction.
Injectable Preanesthetic Preparatio

Good

•Syringe was checked to verify the amount drawn up in the syringe matched the calculations
•Air bubbles were removed
•Catheter was flushed
•Work area was double checked for all items
•The student, with an assistant holding the patient, administered the induction agent according to practice standard protocol
•Determine if more induction agent was needed to intubate
Fair

Syringe was double checked for correct dose. Induction agent was administered.
Poor

Induction agent was administered.
Injectable Anesthetic Induction

Good

•The student waited until the assistant opened the mouth and the dog did not resist opening of the mouth
•The student chose an appropriate endotracheal tube, and the assistant or student did NOT place their hands in the dog’s mouth at any time
•The student placed the endotracheal tube in the trachea
•The student attached the breathing tubes
•The student used roll gauze to secure the endotracheal tube
•The student inflated the cuff
Fair

Placed the endotracheal tube with minimal assistance in the trachea. Attached the breathing tube, secured it and inflated the cuff.
Poor

The student needed full assistance placing the endotracheal tube in the trachea.





Types:





Do more with this rubric:

Preview

Preview this rubric.

Edit

Modify this rubric.

Copy

Make a copy of this rubric and begin editing the copy.


Print

Show a printable version of this rubric.

Categorize

Add this rubric to multiple categories.

Bookmark

Bookmark this rubric for future reference.
Assess
This rubric is still in draft mode and cannot be scored. Please change the rubric status to ready to use.
Share

Publish

Link, embed, and showcase your rubrics on your website.

Email

Email this rubric to a friend.

Discuss

Discuss this rubric with other members.
 

Do more with rubrics than ever imagined possible.

Only with iRubrictm.

n243