Residential Trainer Test
Rubric Code:
Y23967C
By
Tav1980
Draft
Public Rubric
Subject:
Vocational
Type:
Assessment
Grade Levels:
(none)
Your browser does not support iframes.
Desktop Mode
Mobile Mode
Excellent
4 pts
Good
3 pts
Fair
2 pts
Poor
1 pts
Panel wired neatly
Excellent
Panel was wired very neatly. Student expertly utilized 90 bends and zip ties to ensure neatness
Good
Panel was wired neatly. Student utilized 90 bends and zip ties appropriately to ensure neatness
Fair
Panel was wired semi-neat, but could use some work . Student semi-utilized 90 bends and zip ties to ensure neatness
Poor
Panel was not wired neatly
Electrical connections
Excellent
All electrical connections were tight and done appropriately.
Good
Most electrical connections were tight and done appropriately.
Fair
some electrical connections were tight and done appropriately.
Poor
Electrical connections were not tight or done appropriately
Securing Romex
Excellent
All Romex cable was secured according to code
Good
most Romex cable was secured according to code
Fair
Some Romex cable was secured according to code
Poor
Romex cable was not secured according to code
Box connectors
Excellent
Romex box connectors were used when code required
Good
Romex box connectors were used when code required most of the time
Fair
Romex box connectors were used when code required some of the time
Poor
Romex box connectors were not used when code required
Conductor requirement
Excellent
Wire exiting junction boxes to make electrical connections had were long enough according to code
Good
Wire exiting junction boxes to make electrical connections had were long enough according to code most of the time
Fair
Wire exiting junction boxes to make electrical connections had were long enough according to code some of the time
Poor
Wire exiting junction boxes to make electrical connections had were not long enough according to code
device box measurements
Excellent
All device boxes were at the proper height
Good
All device boxes were at the proper height most of the time
Fair
All device boxes were at the proper height some of the time
Poor
All device boxes were not at the proper height
Circuit breaker
Excellent
Circuit breakers were properly selected and installed
Good
Circuit breakers were properly selected and installed most of the time
Fair
Circuit breakers were properly selected and installed some of the time
Poor
Circuit breakers were noy properly selected and installed
Device box depth
Excellent
All device boxes were at the proper depth to account for drywall.
Good
Most device boxes were at the proper depth to account for drywall.
Fair
Some device boxes were at the proper depth to account for drywall.
Poor
Device boxes were not at the proper depth to account for drywall.
Subjects:
Vocational
Types:
Assessment
Discuss this rubric
You may also be interested in:
More rubrics by this author
More Vocational rubrics
More Assessment rubrics
Do more with this rubric:
Preview
Preview this rubric.
Edit
Modify this rubric.
Copy
Make a copy of this rubric and begin editing the copy.
Print
Show a printable version of this rubric.
Categorize
Add this rubric to multiple categories.
Bookmark
Bookmark this rubric for future reference.
Assess
This rubric is still in draft mode and cannot be scored. Please change the rubric status to
ready to use
.
Share
Publish
Link, embed, and showcase your rubrics on your website.
Email
Email this rubric to a friend.
Discuss
Discuss this rubric with other members.
Do more with rubrics than ever imagined possible.
Only with iRubric
tm
.
Copyright © 2024
Reazon Systems, Inc.
All rights reserved.
n98
Your browser does not support iframes.
Your browser does not support iframes.
Your browser does not support iframes.