Electricity Performance 
Grade for Construction class wiring test on mock wall
Rubric Code: GXXX774
Draft
Public Rubric
Subject: Vocational  
Type: Project  
Grade Levels: 9-12

Powered by iRubric Outlet/Switch Wiring
Enter rubric description
  Poor

(N/A)

Fair

(N/A)

Good

(N/A)

Excellent

(N/A)

wire sheathed at proper length

Sheathed at 6"

Poor

Length of wire extends 9"out of the electrical box
Fair

Length of wire extends 8" out of the electrical box
Good

Length of wire extends 7"out of the electrical box
Excellent

Length of wire extends 6" out of the electrical box
Wire

Insulation free from nicks or small cuts which exposes wire.

Poor

More than two wires nicked or cut.
Fair

2 wires nicked or cut
Good

1 wire nicked or cut
Excellent

No wires nicked or cut
Outlet wiring

black to gold(hot)
white to silver(neutral)
ground to green

Poor

Any of the wires hooked to the wrong terminal
Fair

No exceptions because it either works or it doesn't.
Good

All wires hooked to the correct terminal
Excellent

All wires hooked to the correct terminal
And wrapped around the screw in the proper direction
Outlet/Switch Wire connection

Wires were curved and put on the terminals with curve going with tightening direction

Poor

More than two connections going the wrong way screw
Fair

2 going wrong way around the screw
Good

1 wire going the wrong way around the screw
Excellent

All connections correct
Wire Nut connection

Both wires are tight in the nut, no loose wire.
No bare wire showing.

Poor

More than one loose and/or bare wire
Fair

1 loose and or bare wire.
connections tight but two bare wires
Good

no loose or bare wires
Excellent

No Loose or bare wires
Wire twisted in clockwise
direction with tight braided wire
Boxes

switch and outlet boxes placed at correct height

Poor

1 or none were at correct height
Fair

2 were at correct height
Good

3 were at correct height
Excellent

All were at correct height
18" to top of outlet boxes
Running wire properly

power in, from outlet to outlet, outlet to switch.

Poor

Needed help to do it correctly
Fair

Needed two adjustments
Good

Needed one minor adjustment
Excellent

Done correct first attempt




Subjects:

Types:





Do more with this rubric:

Preview

Preview this rubric.

Edit

Modify this rubric.

Copy

Make a copy of this rubric and begin editing the copy.


Print

Show a printable version of this rubric.

Categorize

Add this rubric to multiple categories.

Bookmark

Bookmark this rubric for future reference.
Assess
This rubric is still in draft mode and cannot be scored. Please change the rubric status to ready to use.
Share

Publish

Link, embed, and showcase your rubrics on your website.

Email

Email this rubric to a friend.

Discuss

Discuss this rubric with other members.
 

Do more with rubrics than ever imagined possible.

Only with iRubrictm.



Copyright © 2024 Reazon Systems, Inc.  All rights reserved.
n98